12
Caution: In order to avoid a hazard this
appliance must be installed according to
these instructions for installation
The hob unit can be mounted in any
type of kitchen with a table surface
whose thickness is between 28 mm and
40 mm.
Headroom
The distance to any shelves or tops of a
cabinet under the hob is to be at least 55
mm.
Fixing
Screw the fixing brackets out to such an
extent that they can be turned in under
the table top. Tighten the brackets on to
the table top with an ordinary
screwdriver.
Cut-out measurements
One rectangular hole is sawn out for the
hob combination chosen.
The depth of the cut-out for any unit is:
490 mm
Length of hole = sum of all units`
externally measured length, less 20 mm.
Mounting of Reinforcement
Beams
A reinforcement Beam, with supporting
flanges at each end, is included with
each two-burner unit. For unit
combinations, a reinforcement beam
must be used between each unit.
MIN 55
Mounting
Minimum distance
to wall:
150 mm
Minimum distance to
wall (non flammable
material): 50 mm
Reinforcement
beams
13
It is not necessary to attach the
reinforcement beam to the work top
surface, as it is held in place by a
specially designed moulding, which is
incorporated in the hob units flanges.
The units externally measured
length
290 mm:
Two-zone ceramic-top electric hob
Two-burner gas hob
Grill
Fryer
Wok
Installation of a single unit
When mounting a single unit, be it a
half-or full size unit, in a
worktopsurface which is thicker than
30 mm, it is necessary to make a
special notch in both sides of the cut-
out hole, as shown in the adjacent
drawing.
The purpose of these notches is to
create space for the electrical cables.
4228